(19) Install nipple (6) in diaphragm valve (5).
(20) Install elbow (7) onto nipple (6).
(21) Install flow control (4) in elbow (7).
(22) Install elbow (3) onto flow control (4).
(23) Install nipple (2) in elbow (3).
(24) Install half union (1) onto nipple (2).
(25) Connect both halves of union (1).
r. Install, Control valve Assembly, and Piping. (Figure 3-39).
(1) Position control valve assembly with piping attached. onto support structure of multimedia filter
assembly, and align mounting holes on top and bottom control valve assembly pipe flanges. Check that new
gaskets are in place.
(2) Insert four bolts (10) through new gasket (14) and top pipe flange (16) of control valve assembly (13).
(3) Install, but do not tighten, four nuts (9) on four bolts (10).
(4) Insert four bolts (8) through new gasket (7) and bottom pipe flange (15) of control valve assembly (13).
(5) Install, but do not tighten, four nuts (6) on four bolts (8).
(6) Install U-clamp (5) into mounting bracket and over pipe of control valve assembly (13).
(7) Install, but do not tighten, two lockwashers (4) and two nuts (3) on U-clamp (5).
(8) Install two lock nuts (12) on two clamps (2).
(9) Position two clamps (2) and nuts (12) into mounting bracket.
(10) Install, but do not tighten, two lockwashers (11) and two nuts (12) on two clamps (2).
(11) Adjust and tighten nuts (1) and (12) to secure control valve assembly (13) to multimedia filter
assembly.
(12) Tighten nuts (3), (6), and (9), adjusting piping of control valve assembly (13), as necessary.
3-177