TM 10-4610-229-10
2-5.
STARTUP (CONT)
2
Remove hose from raw water pump discharge adapter.
3
Place hand priming pump strainer in raw water source. Pump priming pump handle until water
can be seen coming from raw water pump discharge adapter.
4
Install hose on raw water pump discharge adapter.
e.
Raw Water Pump Diesel Engine Startup
WARNING
Hearing loss may result from operating system without hearing protection.
CAUTION
To prevent damage to equipment, do not operate pump without water flow.
NOTE
Follow steps 2 thru 4 if battery is operable. Follow steps 5 thru 7 if battery is inoperable.
1
Turn decompression lever right to position 1.
2-98