TM 10-4610-229-10
2-5. STARTUP (CONT)
f. Boost Pump Diesel Engine Startup
WARNING
Hearing loss may result from operating system without hearing protection.
CAUTION
To avoid damage to equipment, do not operate pump without water flow.
1 Turn speed control screw right to move speed control lever to center position.
2 Flip control switch up. Hold bypass switch down and press start button. When engine starts, let up start
button. Hold down bypass switch until engine oil pressure gauge shows 50 psi (3.4 kPa x 100).
2-101