TM 10-4610-229-10
2-5.
STARTUP (CONT)
WARNING
To prevent fire or explosion, keep sparks and open flame away from fuel.
6
Set decompression lever to position 1.
7
If battery operable, flip control switch up. Hold bypass switch down and push start button. Hold
switch and start button down until bubble-free fuel comes out at cap nut. If battery inoperable,
insert crank and turn right until bubble-free fuel comes out at cap nut. Set decompression lever
to 0.
8
Tighten banjo bolt.
b.
Venting Boost Pump Diesel Engine Fuel System
1
Open fuel tank valve. Loosen banjo bolt.
WARNING
To prevent fire or explosion, keep sparks and open flame away from fuel.
2
Pump priming lever on feed pump until fuel comes out at banjo bolt.
3
Tighten banjo bolt.
2-95