2-123. SUCTION ADAPTER ASSEMBLY REPLACEMENT/REPAIR (CONT)
d. Installation
1
Install suction adapter on boost pump. Close cam arms.
2
Install cleaning hose on suction adapter. Close cam arms.
3
Install raw water pump hose on valve V-8 quick-disconnect fitting. Close cam arms.
4
Install valves V-9 and V-10 in barrel connections. Place barrel on barrel stand.
5
Open valves V-8, V-9, and V-10.
Section VII. PREPARATION FOR STORAGE OR SHIPNENT
2-124. LONG-TERM STORAGE
1
Remove reverse osmosis elements from reverse osmosis block assembly. (See TM 10-4610-229-10. )
2
Remove ends from ROWPAC storage units. Place reverse osmosis elements in ROWPAC units. Install ends.
3
Remove and discard cartridge filter elements. (See TM 10-4610-229-10. )
4
Disconnect all hoses. Drain and store.
5
Install caps on pretreatment assembly connections, multimedia filter connections, and high pressure pump
connections.
6
Drain oil from engine crankcases. Fill crankcases with preservative oil (MIL-L-21260). (See paragraphs 2-24, 2-
51, and 2-92. )
WARNING
To prevent fire or explosion, do not bring sparks or open flame near diesel fuel.
7
Drain all fuel tanks. Fill fuel tanks with a mixture of one part preservative oil (MIL-L-21260) and six parts fuel
(VVF-800).
8
Crank engines for 10 seconds each to circulate fluids. (See TM 10-4610-229-10. )
9
For high pressure pump assembly, drain coolant (para 2-98). Fill with fresh coolant.
2-300