TM 10-4610-229-24
2-123. SUCTION ADAPTER ASSEMBLY REPLACEMENT/REPAIR
This task covers:
a.
Removal
c. Assembly
b.
Disassembly
d. Installation
INITIAL SETUP
Use With
Equipment
Condition
Reverse Osmosis Block Assembly
Para
Condition Description
Tools
System configured for
membrane cleaning.
General Mechanic's Automotive
(See TM 10-4610-229-10.)
Tool Kit, item 10, appendix B
a. Removal
1
Close valves V-8, V-9, and V-10.
2
Stand barrel of Hydrakleen-20 on end.
3
Remove valves V-9 and V-10 from barrel connections.
4
Open cam arms. Remove raw water pump hose from valve V-8 quick-disconnect fitting.
5
Open cam arms. Remove cleaning hose from suction adapter.
6
Open cam arms. Remove suction adapter from boost pump.
2-298