TM 10-4610-229-24
2-20. UTILITY LAMP ASSEMBLY REPLACEMENT/REPAIR (CONT)
WARNING
To prevent electric shock, make sure battery is disconnected before performing this procedure.
a.
Removal
1
For raw water pump and boost pump assemblies: Remove four nuts, lockwashers, bolts, and flatwashers.
Remove instrument panel from mounting bracket.
2
For high pressure pump assembly: Remove two mounting screws. Remove back of instrument panel.
3
Desolder lead from rheostat to lamp assembly.
4
For raw water pump and boost pump assemblies: Remove two nuts, starwashers, and screws. Pull lamp
assembly from front of panel.
5
For high pressure pump assembly: Remove two nuts, starwashers, and bolts. Pull lamp assembly from front of
panel.
6
For pretreatment assembly: Cut lead wire. Remove two nuts, flatwashers, and bolts. Remove lamp assembly.
2-61