Item
No.
15.
16.
17.
18.
TM10-4610-232-12
Table 4-1. Unit Preventive Maintenance Checks and Services
Interval
Semi-
Annual
Semi-
Annual
Semi
Annual
Semi
Annual
Item To Be
Checked Or
Serviced
Booster Pump
and Cover
Media Filter Air
Blanket Level ln-
dicator
Media Filter
Diesel Heaters
and Thermostats
Procedure
b. Check cable connector, pins,
inserts, wires and screws for
burnt, damaged, loose or missing
parts.
c. Check inside housing for
cleanliness and insects.
NOTE
Must perform tasks in para-
graphs 4-42 and 4-43 for
checks.
a. Check electrical connector box
and cables for tightness and
proper mounting.
b. Check cable pins, inserts and
wires to screw connectors for
burnt, damaged, loose or missing
parts.
c. Check for loose screws and
mounts on pump motor and be-
tween pump and motor.
d. Check cover for damaged
dampening insulation, loose or
missing mounting hardware.
a. Check for filter media in tub-
ings from the media filter to the
indicator assembly. Clean tubes
if any media is found (Para.
4-52).
b. Check for media in the indica-
tor assembly. Disassemble indi-
cator and clean if any media
found.
c. Test the three switches for
continuity after resetting all flags
to white (para. 4-52).
Check for loose or damaged
components and hardware.
Check for leaks.
a. Check all components for
loose hardware, wires and fuel
lines. Check for fuel leaks.
Not Mission
Capable If:
Connector, pin, insert,
screw or wire damaged,
missing or burnt (Cold
weather operations only).
Any cable connection, pin
or insert damaged.
Any connector, pin, in-
sert, screw or wire dam-
aged, burnt or missing.
Any bolt loose causing
excessive vibration.
Top switch shows conti-
nuity. Middle and bottom
switches do not show
continuity.
Any component damaged
or leaking that will allow
NBC contamination.
Any fuel leaks.
Change 2 4-9