TM 10-4610-232-12
c.
Remove assembled connectors (3 and 4), check valve (5) and tee (6) as a unit.
d.
Remove connector (4) from check valve (5) and check valve (5) from tee (6).
e.
Remove two connectors (3) from tee (6) and remove two gaskets (7) from connectors (3).
REPAIR.
a.
If any leaks are noted, use antiseize tape to wrap male pipe connections prior to assembly.
b.
Replace gaskets (7) if necessary.
NOTE
There should be gaskets in all cam and groove fittings.
c.
Replace all damaged and worn parts.
d.
Repair damaged dust plugs and caps on connectors (3 and 4) by cutting the attaching chain and replacing plug or
cap (para. 4-11).
e.
Replace damaged waste hoses (2).
INSTALLATION.
a.
Install two couplings (3) on tee (6).
b.
Install outlet check valve (5) in tee (6).
NOTE
The arrow on the outlet check valve must point in the direction shown (away from the tee). This valve
stops water from flowing from the ROWPU into the separator.
c.
Install connector (4) on outlet check valve (5).
d.
Install hoses (2) and secure with clamps (1).
e.
Position assembled items (3 thru 7) to separators at connectors (3).
f.
Push separators together and lock connectors (3) to separators.
Change 7 4-106.1