TM 10 4610 232-12
DISASSEMBLY.
a.
Remove the connector (1) with assembled dust cap.
b.
Remove the gasket (2).
c.
Turn elbow (3) off outlet flange (7).
d.
Remove four capscrews (4), lockwashers (5), washers (6) and outlet flange (7).
e.
Remove gasket (8), vortex finder (9) and gasket (10).
f.
Remove the connector (11) with assembled plug.
g.
Remove the gasket (12).
h.
Remove elbow (13) and bushing (14).
i.
Remove two capscrews (15), lockwashers (16), washers (17), capscrews (18), lockwashers (19), nuts (20),
lockwashers (21) and washers (22) and remove inlet flange (23).
I.
Remove four capscrews (24), washers (25), nuts (26), lockwashers (27) and washers (28).
k.
Remove bracket (29), waste housing (30) and gasket (31).
REPAIR.
a.
Clean waste housings (30).
b.
Replace any damaged gaskets (2, 8, 10, 12 or 31).
c.
Replace any damaged components.
d.
Replace any missing or damaged dust caps or plugs (para. 4-11).
e.
Replace the separator assembly (32) if body of separator is cracked or if leaks occur at areas not covered in this
procedure.
f.
Apply antiseize tape to threaded fittings.
REASSEMBLY.
a.
Install gasket (31), waste housing (30) and bracket (29) on separator and secure with four capscrews (24),
washers (25), nuts (26), lockwashers (27) and washers (28).
b.
Install flange (23) and secure with two capscrews (15), lockwashers (16), washers (17), capscrews (18).
lockwashers (19), nuts (20), lockwashers (21) and washers (22).
c.
Install bushing (14), elbow (13), gasket (12) and connector (11) with assembled dust plug.
d.
Install gasket (10) place vortex finder (9) in the top of separator and install gaskets (8) in outlet (7).
CAUTION
Do not overtighten capscrews. The vortex finder may crack. Tighten capscrews evenly and alternately, to
a maximum cross torque of 20 ft-lbs.
e.
Install outlet flange(7)on top of vortex finder (9) and secure with capscrews (4), lockwashers (5), and washers (6).
To prevent leaks, seal the threads of capscrews (4) with pipe thread sealant.
NOTE
It may be necessary to tighten these capscrews further to prevent leaks. Therefore, observe this area for
leaks when the unit is restarted.
INSTALLATION.
NOTE
Brackets on the separators slide into grooves on the frame.
Lift the separators onto the mounting frame.
Change 7 4-108.1