TM 10 4610 232-12
REPAIR
WARNING
Dry cleaning solvent, A-A-711, types I and II, used to clean parts is potentially dangerous to personnel.
Use nonporous gloves when handling solvent or material wet with solvent. Wash hands immediately after
exposure with soap and water and use a lanolin based skin cream to prevent skin drying. Do not use
open flame or excessive heat. Flash point of solvent is 100 F (38 C).
a.
Apply dry cleaning solvent to exposed area near the entrance and exit threads of the cyclone separator.
b.
Remove all dirt and debris from all metal parts.
REASSEMBLY
a.
Install gasket (9) into coupling half (1).
b.
Install elbow (8), check valve (7), reducer (6), coupling half (5), gasket (4) and two plugs (3) onto coupling half (1).
INSTALLATION
Install separator piping by connecting coupling half (2) onto coupling half (1) and then reconnect all hoses to the separator
piping assembly.
Change 7 4-107