TM 10-4610-232-12
Figure 4-52. Valve Actuator Upper Section
(MODEL WTA-060 ONLY)
NOTE
Mark wiring harness wires for identification before removing wires from terminal strip.
(6)
Mark and disconnect wiring harness (10) wires from terminal strip (7).
(7)
Remove connector (8) and nut (9) and remove wiring harness (10).
(8)
Remove screw (11) and washer (12) from mounting bracket (13).
NOTE
Mark positions of switch assembly before removing mounting bracket.
(9)
Remove mounting bracket (13).
(10) Tag and disconnect two wires from solenoid coil (14).
(11) Remove two screws (15) and remove two switch assemblies (16) from bracket (13).
(12) Remove capscrew (17), washer (18), swivel connector (19), fitting (20), air line (21), washer (22), nut (23)and
wave washer (24) from top of solenoid coil (14).
(13) Remove solenoid coil (14).
4-200 Change 7