REASSEMBLY
INSTALLATION
TM 10-4610-232-34
a. Reinstall parts on pressure switches (26 thru 34) as follows:
(1) Install nipple (26) and adapter (27) on switch (34).
(2) Install preformed packing (25) on straight adapter and screw straight adapter (24) into switches (28 thru 32).
NOTE
One tee is used to connect tubes (16 and 18).
(3) Secure tees (23) to straight adapters (24) using the tube nuts on the straight adapters.
(4) Install all plugs (22) on the ends of all tees.
c. Install all pressure switches (28 thru 33 and 34) on panel (35) and secure with washers (21), lockwashers (20) and
capscrews (19).
d. Connect tubes (16 and 18) using tee (23).
e. Install tubes (15, 16 and 18) and secure with hose nuts.
a. Refer to Figure 2-39, sheet 2 and install panel (35) on the ROWPU wall using washers (14), lockvvashers (13) and
capscrews (12).
CAUTION
To avoid damage to ROWPU, check air pressure gages to ensure that air pressure in
the system is zero.
b. Refer to Figure 2-39. sheet 1 and connect seven hoses (11 thru 5) by connecting with hose nuts to their respective
pressure switches as tagged.
c. Close manifold bleed valves (3) and open air tank valve (2).
d. Connect cable P24.
2-148