REPAIR
TM 10-4610-232-34
Figure 2-39. Pressure Switch Panel Assembly (sheet 1 of 2)
(2) Remove the pressure switch from panel (35).
c. Disassemble the components mounted on the pressure switches as follows:
(1) If one end of a tee is plugged, remove plug (22).
(2) Unscrew tee (23) and unscrew straight adapter (24) from the valve body. Remove preformed packing (25) from
straight adapter. Tube nuts will remain on the adapters.
(3) Remove adapter (26) and nipple (27) from pressure switch (34).
a. Repair leaks at male fittings using antiseize tape.
b. Refer to para. 4-10 of TM 10-4610-232-12 and replace damaged nameplates.
c. Replace leaking preformed packings or damaged components.
d. Refer to para. 4-24, TM 10-4610-232-12 and repair tubing if necessary.
e. Replace damaged or missing tube markers (para. 4-10, TM 10-4610-232-12).
2-146
Change 3