TM 10-4610-239-10
TM 08580B-10/1
(3)
Replace holddown ring (2).
CAUTION
To avoid damaging rupture disc, do NOT overtighten holddown screw.
(4)
Reinsert holddown screw (1). Tighten until hand tight (snug), then tighten 1/8 turn with wrench.
3-8.
REPAIR OF CANVAS PRODUCT WATER AND BRINE WATER TANKS
a.
General. Canvas tanks with rubber backing are used to store product water and brine water. Sometimes
these tanks may be cut or punctured. Tanks then leak and must be repaired.
CAUTION
To avoid possible damage, the site should be free from stones or sharp sticks, be fairly smooth, and
covered with the ground cloth before the tank is placed on ground.
b.
Repair. If a tank is punctured, use the oval sealing clamps supplied in the repair kit to make temporary
repairs.
NOTE
The tank does not need to be drained to make these repairs.
(1)
Determine the size of sealing clamp needed. If the hole or slit is up to 2 1/2 inches (6.35 cm) in length,
use the 3-inch (7.62 cm) sealing clamp. If the hole or slit is 2 1/2 to 4 inches (6.35 cm to 10.16 cm) in length, use the 5-
inch (12.7 cm) sealing clamp.
(2)
If necessary, carefully enlarge the slit to slip the narrow side of the inside clamp through.
(3)
Slip the inside clamp through the slit in the tank and rotate it to line up with the slit.
(4)
Rotate the outside clamp to line up with the inside clamp.
(5)
Center both clamps over the slit, pull them together with the rope, and tighten the wing nut as tight as
possible with your fingers.
3-9.
CALIBRATION AND REPAIR OF PORTABLE TDS METER
CAUTION
The TDS meter is an accurate meter. With the exception of calibrating meter or replacing meter battery,
never attempt to service or modify instrument, nor allow it to get wet since moisture will damage the
meter.
a.
Calibration. Perform a calibration check in accordance with para. 2-32c(4) each time before using TDS
meter. Whenever switching to or from seawater sources, meter must be recalibrated in accordance with para. 2-32c(2) or
para. 2-32c(3).
3-28