TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a.
Support pulse dampener (12) and remove two supports (13).
b.
Remove four nuts (4) and screws (5) and two clamps (6) and gaskets (7).
c.
Remove two tubes (1) and two adapters (2) and bushing (3).
d.
Remove four nuts (8) and lockwashers (9), eight flat washers (10), and four screws (11). Discard
lockwashers.
e.
Remove two pipe sections (14), pipe coupling (15), and elbow (16).
INSTALLATION.
NOTE
Apply antiseize tape to pipe threads before installation.
a.
Install elbow (16), pipe coupling (15), and two pipe sections (14).
b.
Position pulse dampener (12) on two supports (13) and install four screws (11), eight flat washers
c.
Install two gaskets (7) and clamps (6) and four screws (5) and nuts (4).
d.
Install bushing (3) and two adapters (2) and two tubes (1).
2-157