TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a. Remove cap (1) from adapter (25) and remove adapter (25) from pipe section (2).
b. Remove two nuts (3), screws (4), clamp (5), and gasket (6) from pipe sections (7) and (8).
c.
Remove four screws (9) from bracket (10).
d. Remove four nuts (11), lockwashers (12), screws (13), and bracket (10) from control panel (14). Discard
lockwashers.
e. Loosen two nuts (15).
f.
While supporting flowmeter (16), remove two nuts (17), lockwashers (18), s rews (19), and two-piece strap
c
(20). Discard lockwashers.
g. Remove pipe sections (2) and (7) with flowmeter (16) from control panel (14).
h. Remove two pipe sections (2) and (7) from flowmeter (16).
i.
Disconnect dissolved solids sensor cable connector (24) from adapter (23) on pipe section (2).
j.
Remove Nomex tape (21) from pipe section (2).
INSTALLATION.
NOTE
Apply antiseize tape to all male pipe threads before installation.
a. Install pipe sections (2) and (7) on flowmeter (16).
CAUTION
Pipe section can be badly damaged by corrosion if it contacts
strap. Be sure to separate pipe section from strap with Nomex
tape.
b. Install Nomex tape (21) on pipe section (2) where two-piece strap (20) will clamp.
c.
Position flowmeter (16) in cutout on control panel (14) and position end of pipe section (2) through hole (22)
in control panel.
d. While supporting flowmeter (16), install two-piece strap (20), two screws (19), new lockwashers (18), and
nuts (17).
e. Tighten two nuts (15).
2-244