TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a. Remove cap (1) from pipe adapter (22) and remove adapter (22).
b. Loosen two nuts (3) on studs (4) and remove two nuts (5), lockwashers (6), and screws (7). Discard
lockwashers.
c.
Remove two-piece strap (8) and Nomex tape (9). Discard Nomex tape.
d. Remove two nuts (10), screws (11), clamp (12), and gasket (13) from pipe sections (14) and (15).
e. Remove two nuts (16), lockwashers (17), and gage clamp (18) from two studs (19). Discard lockwashers.
f.
Remove flowmeter (20) with pipe sections (2) and (14) from control panel (21).
g. Remove pipe sections (2) and (14).
INSTALLATION.
NOTE
Apply antiseize tape to male pipe fittings before installation.
a. Install pipe sections (2) and (14) on flowmeter (20).
b. Position flowmeter (20) in cutout on control panel (21) and install gasket (13), clamp (12), two screws (11),
and nuts (10) on pipe sections (14) and (15).
c.
Wrap pipe section (2) with Nomex tape (9) and position two-piece strap (8) with Nomex tape (9) between
two studs (4) and nuts (3).
d. Install two screws (7), new lockwashers (6), and nuts(5). Tighten two nuts (3).
e. Position gage clamp (18) on two studs (19) and install two new lockwashers (17) and nuts (16).
f.
Install adapter (22) and cap (1) on pipe section (2).
2-240