2-113. REPLACE VENT VALVES: CARTRIDGE FILTER, PULSE DAMPENER, AND MULTIMEDIA FILTER.
This task covers:
a. Removal.
b. Installation.
INITIAL SETUP.
a.
Tools.
Tool Kit (Appx B, Sect III, Item 10).
b.
Materials/Parts.
Antiseize Tape (Appx C, Sect II, Item 17).
c.
Equipment Condition.
ROWPU shut down (TM 10-4610-239-10).
REMOVAL.
NOTE
The cartridge filter, pulse dampener, and multimedia filter vent valve handles are removed the same.
One is shown.
Tag handles before removal.
a.
Working at front of control panel (1), remove nut (2) and handle (3).