TM 10-4610-239-24
TM 08580B-24/3
REMOVAL
a.
Tag and remove flexible tubing connectors (1) and (4) from chemical feed pump heads (3).
b.
Disconnect four hoses (4) from caps (5) on discharge side of feed pump heads (3).
c.
Loosen four nuts (6) and remove four flexible shafts (7) from adjusting spindles (8).
d.
Remove four adjusting spindles (8) and O-rings (9). Discard O-rings.
e.
Remove four nuts (10), lockwashers (11), flat washers (12), and screws (13). Discard lockwashers.
2-276