TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a.
Unwrap cable assembly (1) from distribution pump assembly frame (2).
b.
Remove four screws (3), cover (4), and gasket (5).
NOTE
Tag wires by set before removal.
c.
Pull bundle of four wire sets (6) from conduit box (7).
d.
Set aside bundle of wires with three cream-colored wires.
e.
Tag three other bundles with color of wires from power source.
f.
Remove twine (8) and electrical tape (9) from three tagged wire sets.
g.
Remove screw (10) securing ground terminal lug (11).
h.
Remove nut (12), lockwasher (13), three wire lugs (14), and flat washer (15) from screw (16) on
each set of wires (6) that have been untaped.
i.
Install flat washer (15), lugs of two cream-colored wires (14), lockwasher (13), and nut (12) on screw (16).
CAUTION
Wire insulation can be damaged when wires are pulled through elbow. Be
careful when pulling wires.
j.
From conduit box (7), remove sealing grip locknut (18) and wires (6).
k.
Remove sealing grip (17) from cable assembly.
2-323