TM 10-4610-239-24
TM 08580B-24/3
INSTALLATION. (Cont)
CAUTION
Wire insulation can be damaged when wires are pulled through elbow. Be careful when pulling wires.
a.
Position sealing grip (17) on cable assembly and feed wires (6) through conduit box (7) openig
n
and sealing grip locknut (18). Secure sealing grip locknut (18) on sealing grip (17).
NOTE
There are three sets of motor wires to connect to power source. Each wire
from the power source. Each wire from the power source is added to a
motor wire set in the same way. One is shown.
b.
Remove nut (12) and lockwasher (13) from screw (16).
c.
Install colored wire (14) from power source as tagged, lockwasher (13), and nut (12) on screw (16).
d.
Position ground terminal lug (11) on screw (10) and secure
.
e.
Using electrical tape (9), wrap each wire set (6).
f.
Secure electrical tape (9) on wire set (6) with twine (8).
g.
Position bundle of three wire sets (6) in conduit box (7).
h.
Position gasket (5) and conduit box cover (4) on conduit box (7). Install four screws (3).
i.
Wrap cable assembly (1) on distribution pump assembly frame (2).
2-325