TM 10-4610-239-24
TM 08580B-24/3
INSTALLATION. (Cont)
a.
At ROWPU junction box (1), insert female end of cable connector (2) into male connector (3) and tighten locking
connector (4).
b.
Push taped end of power cable (5) along floor inside ROWPU flatbed trailer' (6) toward and then under ROGEN skid
(7).
c.
Insert and pull taped end of power cable (5) through dus boot (8).
t
d.
Untape power cable ends (9) and strip approximately 12 inches of outside insulation (10) from around five terminal
wires (11).
e.
Strip approximately 1 1/2 inch insulation from each terminal wire (11).
f.
Connect all green wires (five each) to terminal marked LO, connect wire marked L3 (red) to terminal L3, connect
wire marked L1 (white) to terminal L2, and connect wire marked L2 (black) to terminal L1, and tighten five terminal
bolts.
g.
Pull excess power cable (5) through dust boot (8)until cable lies smoothly on platform of ROWPU flatbed trailer (6)
and just under ROGEN skid (7).
h.
Tighten draw string (12) to draw dust boot (8) snugly around power cable (5).
i.
Close ROGEN terminal board access cover (13).
2-342