TM 10-4610-239-24
TM 08580B-24/3
TEST. (Cont)
c.
Connect low-pressure switch to dead weight gage tester or a calibrated pressure gage with a
source of hydraulic or pneumatic pressure.
d.
Apply 11 psi (78.85 kPa) to low-pressure switch as indicated by dead weight gage tester or
calibrated pressure gage.
(1)
If multimeter indicates infinite ohms, go to step e.
(2)
If multimeter indicates 0 ohm, calibrate low-pressure switch.
(3)
If low-pressure switch cannot be calibrated, disassemble low-pressure switch and replace faulty
components.
e.
Apply 10 psi (68.95 kPa) to low-pressure switch as indicated by dead weight gage tester or
calibrated pressure gage.
(1)
If multimeter indicates 0 ohm, test is complete. Disconnect multimeter and position cover
gasket (4), cover (3), and free end of retainer (5) on housing (7) and install four
(2)
If multimeter indicates infinite ohms, calibrate low-pressure switch.
(3)
If low-pressure switch cannot be calibrated, disassemble low-pressure switch and replace faulty
components.
3-103