TM 10-4610-239-24
TM 08580B-24/3
g.
Apply 10 psi (68.95 kPa) to low-pressure switch as indicated by dead weight gage tester or
calibrated pressure gage.
h.
If multimeter indicates 0 OHM, turn adjustment plug (7) counterclockwise one turn more than
needed to change indication to infinite OHMS.
i.
Slowly turn adjustment plug (7) until multimeter indicates 0 OHM.
j.
Install soft copper slug (8) and setscrew (9).
k.
Position cover gasket (10), cover (11), and free end of cover retainer (12) on housing (13) and
3-107