TM 10-4610-239-24
TM 08580B-24/3
3-16. REPAIR HIGH-PRESSURE SWITCH.
This task covers:
a. Disassembly.
INITIAL SETUP.
a.
Tools.
Tool Kit (Appx B, Set III, Item 10).
Calibrated Pressure Gage (Appx B, Sect III, Items 6 and 9).
Variable Hydraulic/Pneumatic Pressure Source (Appx B, Sect III, Items 6 and 9).
b.
Equipment Condition.
c.
General Safety Requirements
WARNING
Compressed air can blow dust into the eyes. Wear eye protection. Do not
exceed 30 psig (207 kPag) air pressure.
3-108