TM 10-4610-239-24
TM 08580B-24/3
ASSEMBLY. (Cont)
g. While holding plate (20) aligned on one end of case (16), position plate (15) on other end. Align mark
made on plate during disassembly with mark on case.
h. Install four bolts (14).
i.
Install fan (12), fan clamp (11), and setscrews (10).
j.
Install fan cover (9) and three screws (8).
k.
Position insulator (6) and conduit box (5) and install two screws (4).
1. Position gasket (3) and conduit box cover (2) and install four screws (1).
TEST.
a. Secure motor to test bench.
WARNING
Electrical high voltages can cause serious injury or death.
Some tests require power to be connected. Always take proper
measures to ensure personal safety.
b. Connect motor wiring to test bench leads.
c.
Connect power and run motor with and without load.
d. Check motor for excessive vibration and fast temperature rise.
e. Disconnect motor from test bench leads.
3-152