TM 10-4610-239-24
TM 08580B-24/3
3-31.
REPLACE BOOSTER PUMP CABLE ASSEMBLY.
This task covers:
a. Removal.
b. Installation.
INITIAL SETUP.
a. Tools. Tool Kit (Appx B, Sect III, Item 10).
b. Materials/Parts.
Tape, Electrical (Appx C, Sect II, Item 18).
c.
Personnel Required.
2
d. Equipment Condition.
Power shut down (power source manual).
ROWPU shut down (TM 10-4610-239-10).
REMOVAL.
NOTE
Note routing of booster pump cable assembly.
a. Remove two screws (1), flat washers (2), and clamps (3) securing booster pump cable assembly (4) to
ROWPU deck.
b. Working at electrical junction box, cut wire ties containing wires between sealing grip (5) and motor
controller K6 (6).
3-157