TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a.
b.
Remove electric motor (3) from drive housing (4).
c.
Loosen setscrew (5) and remove coupler (6) and shaft key (7).
TEST.
a.
Secure motor to test bench.
WARNING
Electrical high voltages can cause serious injury or death. Some tests
require power to be connected. Always take proper measures to ensure
personal safety.
b.
Connect motor wiring to test bench leads.
c.
Connect power and run motor with and without load.
d.
If motor won't start; turn off power, spin shaft by hand, and turn on power while shaft is spinning. If motor
continues to run, stationary switch must be tested after disassembly.
3-226