TM 10-4610-239-24
TM 08580B-24/3
TEST. (Cont)
e.
Disconnect motor from test bench leads.
DISASSEMBLY.
a.
Remove four screws (1), cover (2), and gasket (3).
b.
Remove two screws (4), conduit box (5), gasket (6), conduit spacer (7), and gasket (8). Discard gaskets.
NOTE
Mark both end shields and shell to assist in alignment during assembly.
c.
Remove four bolts (9) and flat washers (10).
CAUTION
Stationary switch mounted on end shield is connected to stator by two
wires. Failure to disconnect wires from stator before moving end shield
more than wire length from stator can damage wires or stator. Be
careful when removing end shield.
NOTE
Tag all wires before removal.
d.
Tap end shield (11) with soft-faced mallet to break bond with shell (12).
e.
Carefully move end shield (11) away from shell (12) while guiding wires (13) th ough side of shell. Disconnect
r
wires (13).
f.
Remove two screws (14), two wire clips (15), and stationary switch (16) from shell (12).
g.
Remove pipe plug (17) and T-drain (18).
NOTE
Place alignment marks on end shield and shell before disassembly.
h.
Tap end shield (19) with soft-faced mallet to break bond with shell (12) and remove shell (12).
i.
Remove two screws with washers (20) from end shield (19).
j.
Remove pipe plug (21) and T-drain (22).
k.
Remove two wavy washers (23) from end of shield (19).
CAUTION
Stator wiring can be damaged by rotor or rotor shaft if it is not removed
carefully.
l.
Remove end shield (19) from rotor (25).
3-228