TM 10-4610-240-10
TM 08580C-10/1
T.O. 40W4-13-21
1-7. EQUIPMENT DATA -continued.
R.O. Pump Motor
Voltage ..............................................................200 VAC, 3-phase
Current...............................................................56.3 amp
Horsepower........................................................20
Frequency ..........................................................60 Hertz
Revolutions Per Minute ......................................1175
Duty Cycle .........................................................Continuous
R.O. Pump
Type ..................................................................Positive displacement
Pumping Capacity ..............................................32 gpm (141 I1pm) 980 psi
(689,038 kg/sqm) head
Oil Capacity .......................................................3.5 quarts (3.3 liters))
Drive .................................................................V-belt
Revolutions Per Minute ......................................500 (maximum)
Backwash Pump Motor
Voltage ..............................................................208-230/460 VAC, 3-phase
Current ..............................................................'26.5-24/12 amp
Horsepower........................................................10
Frequency. .........................................................60 Hertz
Revolutions . ......................................................3450
Duty Cycle .........................................................Continuous
Backwash Pump
Type ..................................................................Centrifugal
Capacity.............................................................120 gpm (454 Ipm) 70 psig (49,217 kg/sqm)
Drive ..................................................................Electric motor
Revolutions Per Minute ......................................3500
Raw Water Pump Motor, 2 each
Voltage ..............................................................208 - 220/440 VAC, 3-phase
Current...............................................................5.8/2.9 amp
Horsepower........................................................2
Frequency ..........................................................60 Hertz
Revolutions Per Minute ......................................3450
Duty Cycle .........................................................Continuous
Raw Water Pump, 2 each
Type...........................................................Centrifugal, self-priming
Capacity.............................................................30 gpm (114 Ipm) 105 ft (32m) head
Drive ..................................................................Electric motor
Revolutions Per Minute ......................................3500