TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-21. CABLE ASSEMBLY (RAW WATER PUMP) MAINTENANCE - continued. .
INSTALLATION
a.
Position sealing grip (1) and gasket (2) on cable assembly (16)
CAUTION
Wire insulation can be damaged when wires are pulled through conduit box Be careful when pulling wires.
b..
Pull four wires from cable (14) into conduit box (4) and install gasket (2) and sealing grip (1).
NOTE
There are four sets of motor wires to connect to cable wires. Each wire from cable is added to a motor
wire set the same way One set is shown, the others are similar
c
Remove nut (10) and lockwasher (9) from screw (5)
d.
Install wire lugs (8) of colored wire from cable (14) as tagged, lockwasher (9), and nut (10)
on screw (5).
e.
Position grounding wire (13) in conduit box (4) and secure with screw (11)
f
Using electrical tape (7), wrap each wire set (3).
g
Tie three wire sets (3) into bundle with twine (12)
h.
Secure electrical tape (7) to each wire sets (3) with twine (12)
i
Position four wire sets (3) in conduit box (4)
j
Position gasket (17) and cover (18) on conduit box (4) and install two screws (19)
k.
Wrap cable assembly (16) on raw water pump assembly frame (15)
l.
Start raw water pump and check for proper operation (TM 10-4610-240-10).
2-110
130