TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-29.
CABLE ASSEMBLY W51 (BOOSTER PUMP) MAINTENANCE - continued.
c
Pull bundle of four wire sets (6) from conduit box (2).
d
Set aside bundle of wires with three cream-colored wires.
e.
Tag three other bundles.
f
Remove twine (12) and electrical tape (3) from three tagged wire sets.
g.
Remove screw (17) securing grounding wire (18).
NOTE
There are three sets of motor wires to disconnect. Each set is removed
the same. One is shown.
h
Remove nut (10), lockwasher (11), three wire lugs (6), and flat washer (5) from screw (4) on each set of wires
(6) that have been untaped.
i.
Install flat washer (5), lugs of two cream-colored wires (6), lockwasher (11), and nut (10) on screw (4).
CAUTION
Wire insulation can be damaged when wires are pulled through elbow.
Be careful when pulling wires.
j.
Loosen nut (15) and remove wires from elbow (13).
k.
Remove nut (15) and gasket (16) from booster pump cable assembly (14).
3-164