TM 10-4610-241-24
TO 40W4-13-42
2-19.
CABLE ASSEMBLY, W43 AND W44 (RAW WATER PUMP) REPLACE - continued.
c.
Installation.
(1)
If removed, install dust cap (23) on cable assembly (Paragraph 2-14).
(2)
Position nut (21), seal ring (20), seal (19), adapter (18) and seal (17) on lug end of cable assembly (22) in
the given order.
(3)
Feed lug end of cable assembly (22) through bottom hole in conduit box (6). providing about 6 inches of
slack.
(4)
Position adapter (18) in cutout of junction box (6) and secure with nut (16).
(5)
Position green grounding wire (15) on junction box (6) and secure with screw (14).
NOTE
Install wires by set as tagged. If tags are lost or illegible, combine wire sets as follows.
Wires from motor are marked and cable wires are color coded:
SET 1
SET 2
SET 3
SET 4
T3
T2
T7
T4
T9
T8
T1
T5
Red
White
Black
T6
(6)
Position washer (12), wire lugs (11) and lockwasher (10) on screw (13) and secure with nut (9). Repeat for
remaining two wire sets.
(7)
Using electrical tape (8), wrap each wire set (6) and secure with twine (7).
(8)
Position four wire sets (5) in conduit box (6) and adjust cable assembly (22) for proper slack.
(9)
Position seal (19) in adapter (18) and seal ring (20) in nut (21), then connect nut to adapter (18) and
tighten.
(10)
Start raw water pump assembly and check for proper operation (TM 10-4610-241-10).
(11)
Wrap cable assembly (22) onto frame of raw water pump assembly
2-104