TM 10-4610-241-24
TO 40W4-13-42
2-21.
CABLE ASSEMBLY W45 (DISTRIBUTION PUMP) REPLACE .
This task consists of:
a.
Removal
b.
Test
c.
Installation
INITIAL SET-UP :
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Multimeter (Appendix B, Section III, Item 3)
Material/Parts Required
Twine (Appendix C, Section II, Item 27)
Tape, Electrical (Appendix C, Section II, Item 20)
Lockwashers (TM 10-4610-241-24P)
Equipment Condition
Reference
Distribution Pump Cable Assembly disconnected from ROWPU (TM 10-4610-241-10).
a.
Removal.
(1)
Unwind cable assembly (22) from frame of distribution pump assembly (1)1.
(2)
Remove four screws (2), cover (3) and gasket (4).
(3)
Pull four wire sets (5) from conduit box (6).
(4)
Set aside wire set with only cream-colored motorwires. These wires do not have to be separated to replace cable
assembly.
NOTE
Tag wires by set before removal (i.e set 1, 2 and 3). If any tagged parts are to be
replaced, be sure to transfer tags to replacement parts before discarding or turning them
in to Supply.
(5)
Tag wires.
(6)
Remove twine (7) and electrical tape (8) from tagged wire sets (5).
(7)
Remove nut (9), lockwasher (10), three wire lugs (11), and flat washer (12) from screw (13) on each wire set (5).
(8)
Remove screw (14), securing grounding wire (15) to conduit box.
(9)
Remove nut (16).
2-108