TM 10-4610-241-24
TO 40W4-13-42
2-21.
CABLE ASSEMBLY W45 (DISTRIBUTION PUMP) REPLACE - continued .
CAUTION
Wire insulation can be damaged when wires are pulled through conduit box. Be careful
when pulling wires.
(10)
Remove cable assembly (22) with attached parts from conduit box and remove gasket (17) from cable assembly.
(11)
Unscrew nut (21) from adapter (18) and remove adapter, seal (19), seal ring (20) and nut (21) from cable
assembly (22).
(12)
As required, remove dust cap (23) from cable connector (24). Refer to Paragraph 2-14.
2-109