TM 10-4610-241-24
TO 40W4-13-42
2-21.
CABLE ASSEMBLY W45 (DISTRIBUTION PUMP) REPLACE - continue d.
c.
Installation.
CAUTION
Wire insulation can be damaged when wires are pulled through conduit box. Be careful
when pulling wires to keep them from chafing.
(1)
If removed, install dust cap (23) on cable assembly (22) (Paragraph 2-14).
(2)
Position nut (21), seal ring (20), seal (19), adapter (18) and gasket (17) on cable assembly (22).
(3)
Feed cable wires thru cutout in conduit box (6) and pull thru from other end to provide about 6 inches of slack.
(4)
Position connector (18) in cutout and install nut (16).
NOTE
Assemble wire sets as tagged; If tags are missing or illegible, assemble wire sets as follows:
SET 1
SET 2
SET 3
SET 4
T3
T2
T7
T4
T9
T8
T1
T5
Red
White
Black
T6
(5)
Position washer (12), lugs of one wire set (11), and lockwasher (10) on screw (13) and install nut (9). Repeat for
other sets.
(6)
Position green grounding wire (15) in conduit box (6) and secure with screw (14).
(7)
Using electrical tape (8), wrap each wire set (5).
(8)
Secure electrical tape (8) on each wire set (5) with twine (7).
(9)
Position four wire sets (5) in conduit box (6) and adjust cable assembly (22) for proper slack.
(10)
When cable assembly (22) is properly positioned on conduit box, position seal (19) in adapter (18) and seal ring
(20) in nut (21) and install nut onto adapter.
(11)
Position gasket (4) and conduit box cover (3) on conduit box (6). Install four screws (2).
(12)
Start distribution pump and check for proper operation (TM 10-4610-241-10).
(13)
Wrap cable assembly (22) on frame of distribution pump assembly (1).
2-112