TM 10-4610-241-24
TO 40W4-13-42
3-13.
CENTRIFUGAL PUMP MOTOR (RAW WATER PUMP) REPAIR - continued.
f.
Test.
(1)
Secure motor to test bench.
WARNING
Electrical high voltage can cause serious injury or death. Always take
proper measures to ensure personal safety.
(2)
Connect motor wiring to test bench leads.
(3)
Apply power and run motor with and without load.
(4)
Check motor for excessive vibration and fast temperature rise.
(5)
Disconnect motor from test bench leads.
3-132