3-16. CENTRIFUGAL PUMP (DISTRIBUTION PUMP) REPAIR - continued.
(5)
Remove four cap screws (11). Then remove bracket (12) and casing (13) as a unit.
(6)
Holding bracket (12) stationary, turn casing counterclockwise (as viewed from pump side) and separate
casing (13) from bracket (12).
(7)
Remove slinger (14) from shaft of motor (17).
(8)
Using drift pin, remove stationary parts of mechanical seal assembly; rubber cup (16) and ceramic disk (15)
from casing (13).
3-137