ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
0016 00
OPERATOR INSTRUCTIONS
MAINTAINING NORMAL OPERATION UNDER USUAL CONDITIONS
DISCHARGE TUBES
SPEED CONTROL
STROKE CONTROL
CP-3
CP-1
CP-2
ANTI-SCALANT HYPOCHLORITE
BISULFITE
Figure 10. Chemical Pumps.
5. Switch the Bisulfite pump with the chemical pump to be replaced as follows (see Figure 10):
a. Disconnect the discharge tube from both the Bisulfite pump and the pump to be changed
out.
b. Connect the discharge tube for the pump being changed out to the discharge outlet of the
Bisulfite pump.
c. Set the speed switch on the pump being changed out to the OFF position.
NOTE
The Bisulfite pump does not start and stop with the HP Pumps. Therefore, the
operator will need to set the Bisulfite switch to ON immediately after starting the
HP pumps and to OFF immediately after setting the Mode Switch to Standby. If the
HP pumps stop due to an alarm shutdown, the operator must also set the Bisulfite
switch to OFF as soon as possible.
6. Set the Bisulfite switch to ON. Prime the replacement chemical pump following the procedure in
WP0014. Refer to
ANTISCALANT AND HYPOCHLORITE CHEMICAL SYSTEMS START-UP
in WP 0014 for the proper settings for the Speed and Stroke after the pump is primed.
7. Tape a note on the Bisulfite pump stating it's current use (antiscalant or hypochlorite). Tape a
similar note on the OCP near the Bisulfite pump switch.
8. Start up the TWPS. Refer to WP 0015. Remember to set the Bisulfite switch to ON after starting
the HP pumps.
INTERCHANGING RAW WATER AND DISTRIBUTION PUMPS
If a raw water or distribution pump is not required for a given deployment, it is available as a spare in the
event that one of the raw water or distribution pumps becomes inoperable.
Interchange raw water and/or distribution pumps as follows:
0016 00-27