ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
0020 00
OPERATOR INSTRUCTIONS
CLEANING, PRESERVATION, AND CLEANING WASTE
VALVE V-706
CLEANING WASTE STORAGE TANK
ADAPTOR
1
A-10
TWPS
ADAPTOR
ADAPTOR A-16
A-16
3
5
6
VALVE V-706
2
P-1 PUMP
4
ADAPTOR
A-16
ADAPTOR A-04
Figure 1. Cleaning Waste Recirculation Set-Up.
WARNING
Chemical hazard. Wear a protective face shield, chemical gloves, and a chemical apron
when handling cleaning wastewater or neutralizing chemicals. Avoid inhaling chemical
fumes or chemical powder. If chemical wastewater or chemical powder spills, immediately
flush the area with water from the auxiliary hose. Failure to observe this warning may
result in mild irritation of the nose, throat, eyes, and skin.
2. Mix and neutralize the cleaning wastewater and neutralizing chemical (refer to Figure 1).
a. Open the three A-16 adaptor valves V-706
b. Start the P-1 pump and run for 10 minutes to mix the cleaning wastewater and
neutralizing chemical.
c. Stop the P-1 pump.
d. Partially unzip the tank top and obtain a wastewater sample.
0020 00-6