ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
0020 00
OPERATOR INSTRUCTIONS
CLEANING, PRESERVATION, AND CLEANING WASTE
NEUTRALIZATION AND PUMP-OUT
When using the cleaning waste storage tank to handle the wastes from Flushing Preservative/Cleaning
Preservation (WP 0026), citric acid is poured into the tank as an initial charge when the tank is set up.
The procedure for adding the citric acid is given by the referenced work packages. After the cleaning
wastes have been discharged into the tank, further neutralization may be accomplished as described.
This section provides the procedures to complete the waste neutralization and for pumping the cleaning
wastewater out of the tank for disposal.
Material:
AC-210 Citric Acid, (1) 20 lb. bucket
(For RO Acid Cleaning waste only) Sodium carbonate, 50 lb. container, (refer to WP 0079, item 40)
Personal protective gear (Box #1)
Chemical apron, 2
Face shield, 1
Chemical gloves, 2 pair
Dust mask, 1
Personnel:
Two Operators/Crew
Equipment Condition:
TWPS Operational
WARNING
Chemical hazard. Wear a protective face shield, chemical gloves, and a chemical apron
when handling cleaning wastewater. Avoid inhaling chemical fumes. If wastewater spills,
immediately flush the area with water from the auxiliary hose. Failure to observe this
warning may result in mild irritation of the nose, throat, eyes, and skin. Promptly change
contaminated clothing after accidental chemical exposure.
1. Setup to recirculate the cleaning wastewater and citric acid (refer to Figure 1).
a. The cleaning waste hoses from the TWPS (1) should have been disconnected from the
cleaning waste storage tank and Adaptor A-10 before beginning this procedure. Refer to
the applicable cleaning or preservation work package.
b. Move the P-1 diesel-driven raw water pump to a position near the tank. The P-2 raw
water pump may be used if the P-1 pump is not available.
c. Connect the female end of one red-banded waste hose (2) to the male end of an A-16
adaptor already on the cleaning waste tank (3).
d. Connect the male end of the waste hose (2) to the P-1 pump inlet.
e. Connect Adaptor A-04 to the pump outlet.
f. Connect the female end of one or more red-banded waste hose(s) as desired (4) to the
male end of Adaptor A-04.
g. Connect the female end of another A-16 adaptor (5) to the male end of the hose(s) (4).
h. Connect the male end of the A-16 adaptor (5) to the female end of an A-16 adaptor
already on the cleaning waste tank (6).
0020 00-5