ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0024 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
MICRO-FILTRATION SYSTEM CLEANING WITH REVERSE OSMOSIS
SYSTEM ACID CLEANING OPERATION UNDER USUAL CONDITIONS
d. If not using the cleaning waste tank, set up the cleaning waste hoses as follows (see
Figure 6):
1) Connect a 2 x 10, red-banded, cleaning waste suction hose to Adaptor A-10.
2) Connect one 50-foot, green banded, raw water discharge hose to the 2 x10, red-
banded cleaning waste hose.
3) Connect one 2x10, red-banded, cleaning waste suction hose to the other end of
the 50-foot hose.
4) Connect Adaptor A-12 to the end of the second cleaning waste hose.
5) Close Adaptor A-12 Valve V-705.
6) Direct A-12 discharge into a depression in the ground away from the TWPS.
A-10
TOP
VIEW OF
TWPS
2 X 10 S-HOSE
4 X 5 S-HOSE
2 X 50 D-HOSE
A-12 VALVE V-705
2 X 10 S-HOSE
Figure 6. MF Acid Cleaning Waste Hose Set-Up Without the Cleaning Waste Tank.
NOTE
When cleaning in preparation for storage (stand down from deployment), the acid
cleaning solution is first used to clean the RO. Following the RO acid cleaning, the
acid cleaning solution is then used to acid clean the MF.
2. Set valves for RO acid cleaning as follows:
a. Make sure the RO feed pump is off.
b. Be sure that Adaptor A-12 Valve V-705 on the 2 x 10 cleaning waste (suction) hoses is
closed (see Figure 5 or Figure 6) for valve location).
0024 00-8