ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0024 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
MICRO-FILTRATION SYSTEM CLEANING WITH REVERSE OSMOSIS
SYSTEM ACID CLEANING OPERATION UNDER USUAL CONDITIONS
c.
Close the distribution tank Adaptor A-15 valve V-525 and disconnect the product hose
(see Figure 7).
PRODUCT HOSE
DISTRIBUTION TANKS
TWPS
V-525
A-15
Figure 7. Distribution Tank Adaptor A-15 Valve V-525.
d. Direct the product utility hose to discharge into the RO feed tank through the open tank
cover (see Figure 8).
e. Open the Product Utility Valve V-511.
f. Open RO Clean Feed Valve V-701.
g. Open Clean Return Valve V-702.
h. Close Clean Mixing Valve V-703.
PRODUCT UTILITY VALVE V-511
CLEAN RETURN VALVE V-702
PRODUCT UTILITY HOSE
RO TANK COVER
CLEAN MIXING VALVE V-703
RO CLEAN FEED VALVE V-701
Figure 8. Valves For RO Acid Cleaning.
0024 00-9