ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0025 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
REVERSE OSMOSIS SYSTEM PRESERVATION OPERATION UNDER
USUAL CONDITIONS
RO VESSEL DRAIN
VALVE V-408
RO FEED PIPING
DRAIN VALVE V-304
HPP OUTLET DRAIN VALVE V-302
HP PUMP OUTLET DRAIN VALVE V-301
TURBOCHARGER REJECT
SIDE DRAIN VALVE V-410
TURBOCHARGER FEED SIDE DRAIN VALVE V-303
HP PUMP FEED VALVE V-212
RO FEED TANK MAIN DRAIN VALVE V-412
RO FEED TANK AUXILIARY
DRAIN VALVE V-210
RO FEED PUMP DRAIN VALVE V-211
Figure 15. Valves to Operate at the End of RO Preservation for Storage.
7. End the RO Preservation in Preparation for Storage as follows:
a. Set the SYSTEM MODE SWITCH to Standby.
b. If using the cleaning waste storage tank, perform the following steps:
1) Close valves V-705 and V-706 on Adaptors A-12 and A-16 that are connected
together on the cleaning waste tank (see Figure 10 for valve location).
0025 00-14