ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0027 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
OPERATION UNDER UNUSUAL CONDITIONS
4. Set up the NBC system for the second filtration pass as described in WP 0010 except as noted
below:
a. If caustic was injected, remove the CP-3 suction tube from the Bisulfite bucket used to
hold the caustic. Set the bucket aside for later use when the TWPS is again used for first
pass operation.
b. The hypochlorite bucket and pump will be set up using "Second Pass Product Water"
c. Set the Speed dial on the antiscalant pump to OFF (fully counterclockwise).
d. MC-TWPS: move the distribution hoses as follows (see Figure 9):
1) Remove Adaptor A-15 with product hose P02 from the "First Pass Product
Water" distribution tank and quickly cap the tank inlet.
2) Remove adaptor A-15 and connect the product hose (P02) to the inlet at the top
of the NBC tank. Up to three hoses may be used.
CAUTION
Do not connect the product hose to the 2nd distribution tank until verifying the
product TDS and Chlorine.
3) Connect one end of the product hose set aside earlier to the outlet at the bottom
of the NBC tank. Place the other end near Adaptor A-15 on the 2nd distribution
tank. If two hoses are required, use the second hose set aside earlier.
4) Do not remove the distribution pump from the "First Pass Product Water"
distribution tank.
DISTRIBUTION PUMP P-7
ADAPTOR A-15
"FIRST PASS PRODUCT WATER"
NBC HYPOCHLORITE TUBE
MC-TWPS
NOZZLE
1 OR 2 PRODUCT
2 OR 3 PRODUCT
HOSES P02
NBC TANK
HOSES P02
NOTE: CONNECT
HOSE TO A-15 ONLY
AFTER VERIFYING
PRODUCT TDS AND
CHLORINE
MF FEED TANK
REMOVE BAG
FILTER S-1
Figure 9. MC-TWPS Second Pass Set-Up for Double Pass NBC Filtration Using One TWPS.
0027 00-12