ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0029 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
PREPARATION FOR MOVEMENT MARINE CORPS UNIT
5. Set the hoses and adaptors aside.
6. Install dust caps on the TWPS raw water inlet, product water discharge hose, and waste outlet.
7. Remove the cap from the end of each distribution discharge (collapsible) hose, tightly roll up the
discharge hoses and secure each with one brown hose strap as indicated in the table below, then
reinstall the caps on the ends of the hoses.
Hose
Hose
Strap
Hose
Hose
Strap
Qty.
Qty.
F02 2-in x 6-ft.
1
12-in.
P05 2-in. x 65-ft.
2
25-in.
F03 2-in x 50-ft.
4
25-in.
P06 5/8-in. x 50-ft.
1
12-in.
F07 3-in. x 10-ft.
2
25-in.
R05 6-in. x 50-ft.
1
36-in.
8. Retrieve the anchor assembly.
9. Open the drain valves on the raw water, MF feed, and product water distribution pumps and drain
the pump casings. Close the valves after all the water has drained. Install the dust caps and
covers on the pump inlet and outlet connections.
10. Disconnect the motor-driven pump power cables at both ends and install the dust covers on the
cable connectors. Tightly coil the cables and set them aside.
11. Install the dust caps on all pump skid junction box receptacles.
12. Close the fuel cock on the diesel pump fuel tank, disconnect the fuel supply and return quick
CAUTION
Potential cause of fuel pump and injection valve failure. Do not leave the fuel lines
for the diesel engine and fuel tank disconnected. Failure to observe this caution
may allow sand and dirt to enter the fuel system and result in fuel pump and
injection valve failure.
13. Couple the two tank fuel lines together and the two diesel engine fuel lines together.
14. Remove the fuel tank.
15. Remove the screen filter from the fuel filler port and drain the fuel from the tank into a fuel can.
0029 00-3