Table 5. General MF System Troubleshooting Continued.
ITEM
MALFUNCTION
POSSIBLE CAUSES
CORRECTIVE ACTION
5
MF Feed Flow display shows
MF Feed Flow Measurement loop failure.
zeros when MF feed pump is
on and observed to be
pumping.
1) If the display is blank, shutdown, set
the Main breaker to OFF and then
back to ON. If this does not correct
the problem, re-program the
does not correct the problem, notify
Unit Maintenance.
2) If the error message "E-PROM
FAILURE (LOAD DEFAULTS?)" is
3) Continue operation. Notify Unit
Maintenance.