The procedures covered in this work package include:
Panel Mounted Flow Transmitter FT-101, FT-401, FT-501 Configuration
Panel Mounted Product Conductivity Transmitter CIT-501 Configuration
PANEL MOUNTED FLOW TRANSMITTER FT-101, FT-401, FT-501 CONFIGURATION:
Equipment Condition:
Operating
Configure the flow transmitters listed below as follows:
- MF Feed Flow Transmitter FT-101
- RO Reject Flow Transmitter FT-401
- Product Flow Transmitter FT-501
NOTE
The transmitter and the sensor that feeds information to the transmitter are configured using
the following keys on the face of the transmitter (see Figure 1):
- Enter key: Pressing this key does two things: It displays submenu and edit/selection
screens, and it enters (saves) configuration values/selections.
- ESC key: Pressing this key always takes the display up on level in the menu tree. The ESC
key can also "abort" the procedure to change a value or selection.
- Left and right arrow keys: Depending on the type of displayed screen, these keys do the
following:
o Measure Screen: At the Measure screen the left and right arrow keys change the
readout (in a continuous loop sequence) to show different measurements.
o Menu Screen: At the Menu screen the left and right arrow key are non-functional.