ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
0033 00
TROUBLESHOOTING PROCEDURES
OPERATOR/CREW TROUBLESHOOTING PROCEDURES
Table 10. Air Compressor Troubleshooting Continued.
ITEM
MALFUNCTION
POSSIBLE CAUSES
CORRECTIVE ACTION
5
Pressurized oil sight glass
Air trapped in pressurized oil system.
change.
6
Oil is foamy and milk colored.
Water in the oil from worn cylinder rings.
Notify Unit Maintenance to change the oil.
Continue operation. Notify Unit
time allows.
7
High oil consumption.
Cylinder rings worn.
Continue operation. Notify Unit
time allows.
8
Air compressor has no oil
Air trapped in oil pump.
pressure.
9
Drive belt has rolled over
Loose or worn belt or loose motor mount
Notify Unit Maintenance
0033 00-24